Power Cables give an assortment of wellbeing measures and are incredibly tough. These Low Tension Power Cables are worked of top notch copper and aluminum for further developed conductivity and are great for moving power to private, business, and modern units. Deeply or multi center links are utilized to build Power Cables. Single center links have a high surrounding temperature and are great channels of both power and hotness.

Power Cables are profoundly utilized and suggested for all power supply needs. They are introduced in Residential, Commercial or modern units and stay for extensive stretch of time without involving the quality. The thickness and the nature of material utilized while building links at Techno Flex Cables are flawless and which is the reason they guarantee the life span and constancy required.

For more information you can contact our experts through our mobile number to assist in giving you more detailed information to meet your requirements. We Techno Flex Cables are acclaimed to be the best in the field and give our competitors a tough fight with regards to our quality and rates! Time and again we have proved that we are better than the best !

Cables that have been developed with the most advanced technologies of our times. Alongside simple usage, we have even ensured the safety of our customers. Compared to other machines, our Flexible Cables techniques are efficient in managing work-hour capacity and enhancing productivity. Alongside high production value, our Flexible Cables go low on maintenance.

Techno flex cable is one of the best Power Cables manufacturer, Power Cables exporter, Power Cables supplier in Mumbai, India. We serve in all over countries. If you want this product then please quote here !

Construction Details :

CONDUCTOR :
Plain bright annealed copper / alluminium, solid / stranded conductor confirming to IS: 8130: 1984.

INSULATION :
Type A, B, & C (HR) grade according to IS: 5831 : 1984 amended up dated.

INNER SHEATH :
Inner sheathing shall done by extrusion or by PVC tape binding that laid up cores shall not loose and prevent to water entering.

ARMOUR :
Gl armour wire / strip provides not only mechanical support but also earthing. The material use an according to IS : 3975 : 1974 amended up dated.

OUTER SHEATH :
Extruded STI / ST2(HR, FRLS, Halogenfree FRLS) type PVC is used according to IS : 5831: 1984.

APPLICATION :
In Thermal Power Station; Petrochemical Refineries; Steel & Cement Plant; Distribution System; Digital Control and Monitoring & Information systems; Air Ports; Building Towers; etc.

Techno Flex manufacture heavy duty Power Cable comprising of cores Single / Two / Three / Three & Half / Four Of Alluminium Conductor, PVC Insulated cores laid up, PVC Inner Sheathed OR PVC tape binding, GI wire / Strip Armoured & overall PVC sheathed cable confirming to IS : 1554 : Part-I.

Basic assumption for Current ratings :

  1. Max. Conductor Temp. : 70°C
  2. Thermal resistivity soil : 150°C CM/W
  3. Thermal resistivity of rvc : 650°C CM/W
  4. Ground temperature : 30°C
  5. Amb. air temperature : 40°C
  6. Depth oflaying : 75 cm (highest pt. of cable laid)

Rating Factors :

  1. Rating Factor for depth of laying Twin & Multicore Cables

  2. Depth Of laying cm upto 25mm2 Above 25mm2 & 300mm2 Above & 300mm2 Multicore
    70 1 1 1 1
    90 0.99 0.98 0.97 0.99
    105 0.98 0.97 0.96 0.98
    120 0.97 0.96 0.95 0.97
    150 0.96 0.94 0.92 0.96
    180 or More 0.95 0.93 0.91 0.95

  3. Rating Factor for the Single Core Cables (AC) in the formation in Air Applied to the corresponding ratings for trefoil groups in air.

  4. Nominal Area Of Conductor mm2 Rating Factor
    Upto & Including 185 1.07
    240 1.10
    300 1.08
    400 1.04
    500 1.00
    600 1.00

  5. Rating Factor for variation in underground temperature for cables laid direct in ground & laid in duct.

  6. Ground Temperature 0C 15 20 25 30 35 40 45
    Rating Temperature 1.17 1.17 1.17 1.17 1.17 1.17 1.17

  7. Rating Factor for variation in underground temperature for cables laid direct in ground & laid in duct.

  8. Ground Temperature 0C 15 20 25 30 35 40 45
    Rating Temperature 1.33 1.25 1.16 1.09 1.0 0.90 0.83

Short Circuit Rating Of Alluminium Conductor Cable :

Techno Flex cables manufacturing method based on quality assurance plan & use of high standard raw material, therefore it withstand high Magnitude of short circuit rating. It is calculated as under:

where Ish --> short circuit ratings in r.m.s. amp.
t --> duration of short circuit in seconds
A --> Area of conductor in sq.mm

Tabulated The Constant For Different Duration Of Short Circuits :

Duration of Short Circuit in sec. 1 Cycle = 0.02 sec 2 Cycle = 0.04 sec 5 Cycle = 0.1 sec 10 Cycle = 0.2 sec 25 Cycle = 0.5 sec 50 Cycle = 1.0 sec 2 sec 3 sec 4 sec 5 sec
Short Circuit constant Per unit area 536 378 239 169 107 75.7 53.0 43.6 37.8 34
Example: Short Circuit rating of 70 sq.mm area of conductor with short duration 0.5 sec = 70 x 107 = 7490A


Recommendation For Installation : Cables are the most important asset of any organization. Any damage to it will result in break down of the complete plant & machinery, hence proper attention should be paid while handling and laying them. So for its silent features which should be kept in view during installation as under:-

  1. Before laying the installation ofthe cable, It should be checked by meggar as a preliminary check against any probable fault.

  2. The drum should be always rolled in the direction of the arrow or opposite to the outside cable end.

  3. Avoid the possibility cable twist which will brutally damage the cable because cable have itself twisting force.

  4. Properly check the sequence of cores & no crossing of cores while connecting, also decide the direction in which the cable is to be pulled.

  5. Possible bending radius should be 12 times the overall diameter of the cable to be maintained. But at any case it should not be less than 8 times.

  6. In low temperature area the bending should not be very small radius because PVC compound become stiff & brittle and it shall get crack.

  7. All joints terminations armour wires & external metallic bonding should be connected to the earth, wherever possible armour at one end of the cable should be connected to main earth system at the supplying end by employing metallic connectors. Precautions should be taken to eliminate the chemical & by metallic corrosion ofthe earth connector.

  8. The design of the box & composition of the filling compound should provide an effective sealing against entry of moisture to conductor & annour connector.

  9. If hot pouring protective compounds are used, the temperature of the compound while pouring should not exceed 150°C.

  10. Where the cables are crossing the roads, the same should be laid in concrete ducts & avoid the sharp edges of concrete ducts in other hand cable may be damaged.

  11. We strongly recommend the user that after installation, 2KV DC voltage test should be carried out, through the each core before earthing.